Försiktighetsåtgärder och juridiska anmärkningar



⬇️ multi ⬇️

BellaBambi® Cups

Attention

This device is not intended to be used by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and/or knowledge, unless they have been supervised or instructed on how to use the device by a person responsible for their safety. Children should be supervised to ensure they do not play with the device. This device can be used by children from 8 years and older and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been supervised or instructed on how to use the device safely and understand the risks associated with it.

Application & principle

Loading image:

Press, attach, and release. You can drag the suction cup over the skin or let it stay in place.

If you find the application uncomfortable, you can squeeze BellaBambi® less tightly or use a softer intensity. Always pay attention to your own well-being!

NOTE:
Do not use BellaBambi® statically in one place for more than 20 seconds to avoid skin marks. Static application on the face is completely excluded.

Do not use on:

Nipples, genitals, anus, eyes (eyelids), lips and oral cavity, on lymph nodes, in the armpit and in the groin.

Use only after consultation with a doctor for

Pregnancy, acute injuries, open wounds, inflammations, varicose veins, tendency to bruising, wounds caused by diabetes and vascular diseases, irritating skin diseases such as psoriasis or hives, treatments with blood-thinning medications, tumors, Sudeck's disease, as well as all unclear and acute diseases.

Cleaning & storage

BellaBambi® is very easy to clean in the dishwasher or by hand with mild soapy water. After drying, treat with a disinfectant suitable for silicone (without propanol, phenol derivatives, or alkylamines (glucoprotamin)). Note: If BellaBambi® is very dirty, you can also boil it - just like a pacifier. Then place BellaBambi® in a clean pot, cover it completely with water, and boil it for at least five minutes.
Children must not clean the cup without supervision.
You can find suitable cleaning agents and disinfectants at www.bellabambi.de

Recommendations

For some applications, an oil to support lubrication is helpful. BellaBambi® can also be combined with hyaluronic acid, cellulite creams, or body lotions.

Guarantee

We provide a two-year manufacturer warranty on all cups. Please note that this only applies if you use the combination and cleaning products recommended by the manufacturer.
You can find the warranty terms here:
www.bellabambi.de/garantie


BellaBambi® multi

Thank you for your purchase
Congratulations on your purchase of BellaBambi® multi. You now have a universally useful and durable product at hand when it comes to care and well-being. The suction cups and connecting tube are skin-friendly and are exclusively manufactured in Germany. To ensure you get as much enjoyment as possible from your new product for as long as possible, we ask you to read this instruction manual carefully.
Thank you very much!
Your BellaBambi® team

Loading image:

Description of

1. Intensity regulator
2. Connection for hose
3. On/off button

Explanation of symbols

WARNING Warning of risk of personal injury or danger to your health

NOTE Safety instructions for any damage to the device/accessories

Reference to important information

Use only in enclosed spaces

Isolated protective device in protection class II

Not suitable for children under three years

Purpose and principle

With BellaBambi® multi you can give yourself or others a beneficial suction massage. Massage can have a relaxing or stimulating effect and is often used to treat tension, adhesions, pain, and fatigue in the areas of beauty, wellness, and sports.
BellaBambi® multi is intended for external use in the form of a vacuum massage of individual parts of the human body. It is not a medical product, must not be used for therapeutic purposes, and cannot replace medical treatment.

Do not use BellaBambi® multi under these circumstances:

- Risk of pregnancy
- Skin injuries, skin defects, and skin inflammation (e.g., abrasions, wounds, sunburn)
- Bleeding tendencies or persons with blood clotting disorders
- Diseases of blood and lymph vessels
- Skin cancer
- Do not use BellaBambi® on:
◦ Eyes and eyelids
◦ Ear canal, lips, and oral cavity
◦ Nipples and genitals
◦ Anus
- Known allergies to product materials and accessory components.

Use BellaBambi® multi only after a thorough examination of the circumstances in cases of: pregnancy, Sudeck's disease, cancer and tumor diseases, bleeding tendency and thrombotic diseases, blood-thinning medications, irritating skin diseases (e.g. psoriasis, urticaria) as well as all unclear diseases.

Use BellaBambi® multi only after a thorough examination of the circumstances in cases of: pregnancy, Sudeck's disease, cancer and tumor diseases, bleeding tendency and thrombotic diseases, blood-thinning medications, irritating skin diseases (e.g. psoriasis, urticaria) as well as all unclear diseases. If your skin reacts sensitively to the application (e.g., rapid onset of bruising, persistent redness or itching) or if you experience general discomfort and pain, you should stop immediately and contact a doctor.

If BellaBambi® is left in place, note our empirical values on how the skin may react with medium absorption capacity:

Sensitive skin

Pressure point : until ≈ 1-2 min
Redness : until ≈ 2-3 min
Brand for cupping : until ≈ 5 min

Normal hud

Pressure point : until ≈ 2 min
Redness : until ≈ 4 min
Brand for cupping : until ≈ 7 min

Robust HUD

Pressure point : until ≈ 5 min
Redness : until ≈ 7 min
Brand for cupping : until ≈ 9 min

* Cupping marks should not be confused with hematomas, so-called "bruises," which are caused by traumatic effects (blows, falls, etc.). Cupping marks are signs that blood leaks into the fascial tissue, which (usually) occurs without vascular damage and is never (!) painful. Furthermore, these marks disappear without the yellow-green discoloration that is typical of hematomas.

Safety instructions

Note: For your own safety, you should carefully follow the following safety instructions and make other users of the device aware of them. Keep this manual in a safe place.

- Read this instruction manual carefully and completely before use and follow the instructions in the manual.
- The vacuum pump and applications can be placed back in the bag after use. Therefore, there is no packaging material that needs to be discarded.
- The device may only be connected to alternating current with a voltage that corresponds to the rating plate on the pump housing.
- Do not pull the power cable over sharp edges and do not pinch it, do not let it hang down and protect it from heat and oil.
- Make sure there is a power outlet near the installation site.
- Lay the power cable and connection hose in such a way that no one can trip over them.
- The device must not be placed on the bathroom floor.
- Do not use the device near water in bathtubs, washbasins, or other containers.
- Never immerse the device in water. Never let liquids enter the device.
- Do not cover the device with clothes, towels, or similar (risk of overheating!).
- Do not place the device on hot surfaces such as stovetops or similar and do not use it near open flames.
- Turn off the device after each use. The power plug must not be pulled out of the socket by the cable or with wet hands.
- Do not use the device unattended.
- Always unplug the power plug from the wall socket before cleaning and maintenance of the device.
- Check the device before each use to see if it is damaged. Do not use the device if
◦ the pump housing or power supply cables are damaged.
◦ the unit has been dropped.
- If any of the above cases occur, send the device to our service department for inspection or professional repair (see page). Never attempt to repair the device yourself.
- This device can be used by children from eight (8) years and older and by persons with reduced physical, sensory or mental capabilities or lack of experience and/or knowledge, if they have been supervised or instructed on how to use the device safely and understand the risks involved. Children must not play with the device. Cleaning and user maintenance must not be performed by children without supervision.
- Strictly follow the dosages and maximum time limits specified in this instruction manual!
- Do not use any additional parts not recommended by the manufacturer.

Commissioning

1. The applications must be cleaned before each use. See Cleaning on page 6.
2. Select the BellaBambi® application that fits the body part and connect it to the vacuum pump using the connection hose.
BellaBambi® mini is especially suitable for narrow parts of the body, face, hands, and feet.
BellaBambi® original can be used on the whole body, e.g. back, calves, or neck.
BellaBambi® maxi is used for large areas, e.g. on the back, stomach, or thighs.
3. Plug in the power cord and turn on the vacuum pump.
4. Set the maximum suction strength and put on the BellaBambi® application. As soon as it has been suctioned in, reduce the suction strength if necessary until it is noticeable but not uncomfortable.
5. Use the product in accordance with its intended purpose and the safety instructions in this user manual.
6. Clean after use. See Cleaning page 6.
7. Turn off and unplug the power plug.

For your safety, we have installed a timer that automatically turns off the vacuum pump after 15 minutes. You can restart the device at any time using the on/off button.

Application

In general, you should only massage the skin or muscles and never directly on the spine or bone protrusions. Glands and lymph nodes must not be massaged.

Always adjust the suction power to your comfort level.

Cleaning

Loading image:

Clean only the vacuum pump with a lightly dampened, never dripping wet, cloth. Add a few drops of cleaning agent if necessary.

Loading image:

1. Wash/rinse the BellaBambi® application with warm soapy water or regular dish detergent, either by hand or in a dishwasher.
2. Dry the BellaBambi® application thoroughly or let it dry.
3. Spray with a disinfectant suitable for silicone, i.e. without phenol derivatives or alkylamines (glucoprotamin).
4. Let the disinfectant act according to the manufacturer's instructions.
5. Rinse off any disinfectant residue thoroughly with clean water.
6. Dry the BellaBambi® application thoroughly again or let it dry.

What should I do if problems arise?

Applications do not freeze

The unit is not connected to the power grid or is turned off. → Connect the power cable and turn on the device.

The applications are not properly connected. → Check the connections on the vacuum pump and on the application.

The skin area to be treated is very hairy. → Apply massage oil or cream, shave if necessary.

The opening on BellaBambi® cannot rest entirely on the body part. → Choose a smaller BellaBambi®, or squeeze BellaBambi® slightly to reduce the contact area

The timer has expired → Press the on/off button

-

The application is unpleasant.

Suction power is set too high. → Reduce the suction power so that it is noticeable but not uncomfortable.

No skincare product is used. → Use a moisturizing skincare product if possible.

Too little/wrong skincare product used. → Use a more moisturizing skincare product.

Technical data and environmental conditions

The permitted environmental conditions specify the limits within which BellaBambi® multi can be used without risk of damage.


Permitted environmental conditions:

  • +10°C to +40°C (in operation)
  • -18°C to +60°C (storage)
  • 30% to 75% relative humidity

Power consumption: 230 Vac, 50 mA, 50/60 Hz

-

Intensity min. (knob turned all the way to the left) = -50 mbar ( Negative pressure at the device outlet )

Max intensity (knob turned all the way to the right) = -280 mbar ( Negative pressure at the device outlet )

Maintenance and repair

Repairs of the vacuum pump may only be carried out by the manufacturer. The device must not be opened under any circumstances. Do not perform any unauthorized interventions on the device. Otherwise, the warranty will become void. For all necessary repair and maintenance work, contact the following address:


Bamberg Precision Parts Made of Elastomers eK
Industriestraße 25
D-89423 Gundelfingen
Phone: + 49 (9073) 1234
Fax: + 49 (9073) 1334
info@bellabambi.de
www.bellabambi.de

Waste management

Your device contains many raw materials that can be recycled. Therefore, return the device to a collection point in your city or municipality. Do not throw old devices in the residual waste! Ask at your local recycling center about the possibilities to recycle your device. If municipal waste management is not possible, you can submit the device free of charge to Bamberger for professional waste management.

Back to top