Skip to content

Предпазни мерки правни указания



⬇️ multi ⬇️

BellaBambi® Cups

Attention

This device is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities or lack of experience and/or knowledge, unless they have been given supervision or instructions concerning the use of the device by a person responsible for their safety. Children should be supervised to ensure that they do not play with the device. This device may be used by children aged 8 years and above and by persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instructions regarding the safe use of the device and understand the associated hazards.

Application and principle

Loading image:

Press, dress, and relax. You can pull the suction cup onto your skin or leave it in place.

If you find the application uncomfortable, press BellaBambi® more lightly or use a softer intensity. Always pay attention to your own well-being!

WARNING:
Do not use BellaBambi® statically in one place for more than 20 seconds to avoid marking the skin. Static application on the face is completely excluded.

Do not use on:

Grains, genitals, anus, eyes (eyelids), lips and oral cavity, lymph nodes, in the area of the armpits and groin.

Use only after consulting a doctor

Pregnancy, acute injuries, open wounds, inflammations, varicose veins, tendency to bruise formation, ulcers caused by diabetes and vascular diseases, irritant skin diseases such as psoriasis or hives, therapies with blood-thinning medications, tumors, Sudek's disease, and all unclear and acute diseases.

Cleaning and storage

BellaBambi® is very easy to clean in a dishwasher or by hand with soft soapy water. After drying, treat with a disinfectant suitable for silicone (without propanol, phenol derivatives, or alkylamines (glucoprotamine)). Please note: If BellaBambi® is very dirty, you can also boil it - just like a baby mattress. To do this, place BellaBambi® in a clean container, cover it completely with water, and boil it for at least five minutes.
Children should not clean the cup unsupervised.
You can find suitable cleaning agents and disinfectants at www.bellabambi.de

Recommendations

For some applications, it is useful to use oil to assist lubrication. BellaBambi® can also be combined with hyaluronic fluid, anti-cellulite creams, or body lotions.

Warranty

We provide a two-year manufacturer's warranty for all cups. Please note that this only applies if only combinations and cleaning products recommended by the manufacturer are used.
You can find the warranty conditions here:
www.bellabambi.de/garantie


BellaBambi® multi

Thank you for your purchase
Congratulations on purchasing BellaBambi® multi. You now have a universally applicable and durable product at hand when it comes to care and well-being. The suction cups and connecting tube are skin-friendly and are exclusively made in Germany. To achieve maximum success and enjoy your new product for as long as possible, please read these instructions for use carefully.
Thank you very much!
Your BellaBambi® team

Loading image:

Description of

1. Intensity regulator
2. Hose connection
3. On/off button

Explanation of the symbols

WARNING Warning of risk of injury or danger to your health

WARNING Safety instructions in case of device/accessory malfunction

Reference to important information

Use only indoors

Protective insulated device of protection class II

Not suitable for children under three years of age

Purpose and principle

With BellaBambi® multi you can give yourself or others a soothing massage with negative pressure. The massages can have a relaxing or stimulating effect and are often used to treat tension, adhesions, pain, and fatigue in the areas of beauty, wellness, and sports.
BellaBambi® multi is intended for external use in the form of vacuum massage on individual parts of the human body. It is not a medical product, should not be used for therapeutic purposes, and cannot replace medical treatment.

Do not use BellaBambi® multi under these circumstances:

- Pregnancy at risk
- Skin injuries, skin defects, and skin inflammations (e.g., abrasions, ulcers, sunburns)
- Tendency to bleed or people with blood clotting disorders
- Diseases of the blood vessels and lymphatic vessels
- Skin cancer
- Do not use BellaBambi® on:
◦ eyes and eyelids
◦ ear canal, lips, and oral cavity
◦ nipples and genital organs
◦ anus
- Known allergies to the product material and additional components

Use BellaBambi® multi only after a thorough investigation of the circumstances in case of: pregnancy, Sudek's disease, cancer and tumor diseases, tendency to bleeding and blood clotting disorders, use of blood-thinning medications, irritant skin diseases (e.g. psoriasis, urticaria), as well as all unclear diseases.

Use BellaBambi® multi only after a thorough investigation of the circumstances in case of: pregnancy, Sudek's disease, cancer and tumor diseases, tendency to bleeding and blood clotting disorders, use of blood-thinning medications, irritant skin diseases (e.g. psoriasis, urticaria), as well as all unclear diseases. If your skin reacts sensitively to the application (e.g. rapid bruising, persistent redness, or itching) or if you experience general discomfort and pain, please stop immediately and consult a doctor.

If BellaBambi® is left in place, please note our empirical values for how the skin may react with average absorption:

Sensitive skin

Pressure point : to ≈ 1-2 min
Redness : to ≈ 2-3 min
Marking on the cup : to ≈ 5 min

Normal skin

Pressure point : to ≈ 2 min
Redness : to ≈ 4 min
Marking on the cup : to ≈ 7 min

Healthy skin

Pressure point : to ≈ 5 min
Redness : to ≈ 7 min
Marking on the cup : to ≈ 9 min

* Bruise marks should not be confused with hematomas, the so-called "bruises," which are caused by traumatic impacts (blows, falls, etc.). Bruise marks indicate blood leakage into the fascia tissue, which (usually) occurs without damage to blood vessels and is never (!) painful. Moreover, these marks disappear without the yellow-green coloring characteristic of hematomas.

Safety instructions

Attention: For your own safety, please carefully follow the following safety instructions and familiarize other users of the device with them. Keep these instructions in a safe place.

- Read these instructions for use carefully and completely before using the device, and follow the sequence of procedures.
- The vacuum pump and accessories can be placed back in the bag after use. Therefore, there is no packaging material that needs to be disposed of.
- The device can only be connected to alternating current with voltage in accordance with the rating plate on the pump housing.
- Do not pull the power cord over sharp edges and do not pinch it, do not allow it to hang down, and protect it from heat and oil.
- Make sure there is an electrical outlet near the installation site.
- Place the power cord and connecting hose in such a way that no one can trip over them.
- The device must not be placed on the bathroom floor.
- Do not use the device near water contained in bathtubs, sinks, or other containers.
- Never immerse the device in water. Never allow liquids to enter the device.
- Do not cover the device with clothes, towels, or similar items (risk of overheating!).
- Do not place the device on hot surfaces such as stoves or similar, and do not use it near open flames.
- Turn off the device after each use. The power plug must not be pulled from the socket by the cable or with wet hands.
- Do not operate the device unattended.
- Always unplug the device before cleaning and maintenance.
- Check the device for damage before each use. Do not use the device if
◦ the pump housing or power cables are damaged.
◦ the device has been dropped.
- If any of the above cases occur, send the device to our service department for inspection or professional repair (see page). Never attempt to repair the device yourself.
- This device can be used by children aged eight (8) years and above and by persons with reduced physical, sensory, or mental capabilities or lack of experience and/or knowledge if they have been given supervision or instruction concerning the safe use of the device and understand the hazards involved. Children must not play with the device. Cleaning and user maintenance must not be carried out by children without supervision.
- Please strictly observe the doses and maximum durations specified in these instructions for use!
- Do not use additional parts that are not recommended by the manufacturer.

Commissioning

1. The applications must be cleaned before each use. See cleaning on page 6.
2. Select the BellaBambi® application that corresponds to the body part, and connect it to the vacuum pump using the connecting hose.
bellaBambi® mini is especially suitable for narrow body parts, face, arms, and legs.
bellaBambi® original can be used for the whole body, e.g. back, calves, or neck.
bellaBambi® maxi is used for applications on large areas, e.g. on the back, abdomen, or thighs.
3. Plug in the power cable and turn on the vacuum pump.
4. Set the maximum suction power and place the BellaBambi® application. As soon as it is suctioned, reduce the suction power if necessary until it becomes noticeable but not unpleasant.
5. Use in accordance with the purpose and safety instructions in these instructions for use.
6. Clean after use. See Cleaning page 6.
7. Turn off and unplug from the electrical outlet.

For your safety, we have installed a timer that automatically turns off the vacuum pump after 15 minutes. You can restart the device at any time by using the power button.

Application

As a rule, always apply only on the skin or muscles and never directly on the spine or bony prominences. Glands and lymph nodes should not be massaged.

Always adjust the suction strength according to your comfort level.

Cleaning

Loading image:

Clean the vacuum pump only with a slightly damp, but never wet cloth. If necessary, add a few drops of cleaning detergent.

Loading image:

1. Wash/clean the BellaBambi® applicator with warm soapy water or with a commercially available dishwashing liquid, by hand or in a dishwasher.
2. Dry the BellaBambi® applicator thoroughly or let it air dry.
3. Spray with a disinfectant suitable for silicone, i.e. without phenol derivatives or alkylamines (glucoprotamin).
4. Let the disinfectant act according to the manufacturer's instructions.
5. Rinse off the disinfectant residues thoroughly with clean water.
6. Again, dry the BellaBambi® applicator thoroughly or let it air dry.

What to do in case of problems?

The application does not freeze

The device is not connected to the power supply or is turned off. → Connect the power cable and turn on the device

The applications are not connected properly. → Check the connections of the vacuum pump and the application.

The treated skin area is heavily hairy. → Apply massage oil or cream, if necessary, shave.

The opening of BellaBambi® cannot lie entirely on the part of the body. → Choose a smaller BellaBambi® or
Squeeze BellaBambi® slightly to reduce the contact area.

Timer expired → Press the power button.

-

The application is unpleasant.

An incorrect suction power is set. → Reduce the suction power so that it is noticeable but not unpleasant.

No skincare products are used. → If possible, use a moisturizing skincare product.

Too little/incorrect skincare product is used. → Use a more moisturizing skincare product.

Technical data and environmental conditions

Permissible environmental conditions indicate the limits within which BellaBambi® multi can be used without risk of damage.
Permissible environmental conditions:

  • +10°C to +40°C (during operation)
  • -18°C to +60°C (during storage)
  • Relative humidity from 30% to 75%

Power consumption: 230 V, 50 mA, 50/60 Hz

-

Intensity min. (the control is turned all the way to the left) = -50 mbar ( Negative pressure at the device output )

Maximum intensity (control turned all the way to the right) = -280 mbar ( Negative pressure at the device output )

Support and repair

Repairs of the vacuum pump can only be carried out by the manufacturer. The device must not be opened under any circumstances. Do not perform any unauthorized manipulations with the device. Otherwise, you will void your warranty. For all necessary repair or maintenance activities, please contact the following address:


Bamberg Precision Parts Made of Elastomers eK
Industriestraße 25
D-89423 Gundelfingen
Phone: + 49 (9073) 1234
Fax: + 49 (9073) 1334
info@bellabambi.de
www.bellabambi.de

Waste disposal

Your device contains many raw materials that can be recycled. Therefore, return the device to a waste collection point in your city or municipality. Please do not dispose of old appliances in residual waste! Please check with the local recycling center for recycling options for your device. If disposal in the municipality is not possible, you can return the device to Bamberger free of charge for professional disposal.

Back to top